Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 344
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38578335

RESUMO

PURPOSE: To assess the possible benefits of the use of perceptual learning and dichoptic therapy combined with patching in children with amblyopia over the use of only patching. METHODS: Quasi-experimental multicentric study including 52 amblyopic children. Patients who improved their visual acuity (VA) by combining spectacles and patching were included in patching group (PG: 20 subjects), whereas those that did not improved with patching performed visual training (perceptual learning + dichoptic therapy) combined with patching, being assigned to the visual treatment group (VT: 32 subjects). Changes in VA, contrast sensitivity (CS), and stereopsis were monitored during a 6-month follow-up in each group. RESULTS: Significant improvements in VA were found in both groups at 1 month (p < 0.01). The total improvement of VA was 0.18 ± 0.16 and 0.31 ± 0.35 logMAR in PG and VT groups, respectively (p = 0.317). The Wilcoxon effect size was slightly higher in VT (0.48 vs. 0.54) at 6 months. An enhancement in CS was observed in the amblyopic eye of the VT group for all spatial frequencies at 1 month (p < 0.001). Likewise, the binocular function score also increased significantly in VT group (p = 0.002). A prediction equation of VA improvement at 1 month in VT group was obtained by multiple linear regression analysis (p < 0.001, R2 = 0.747). CONCLUSIONS: A combined treatment of visual training and patching is effective for obtaining a predictable improvement of VA, CS, and binocularity in patching-resistant amblyopic children.

2.
Sci Rep ; 14(1): 8592, 2024 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-38615153

RESUMO

Multifocal contact lenses (MCLs) are one of the solutions to correct presbyopia, but their adoption is not widespread. To address this situation, visual simulators can be used to refine the adaptation process. This study aims to obtain accurate simulations for a visual simulator (SimVis Gekko; 2EyesVision) of daily soft MCL designs from four manufacturers. In-vitro characterization of these MCLs-several powers and additions- was obtained using NIMO TR-1504. From the averaged relative power profiles across powers, phase maps were reconstructed and the Through-Focus Visual Strehl metric was calculated for each MCL design. The SimVis Gekko simulation corresponding to each MCL design was obtained computationally and bench-validated. Finally, the MCL simulations were clinically validated involving presbyopic patients. The clinical validation results show a good agreement between the SimVis Gekko simulations and the real MCLs for through-focus visual acuity (TF-VA) curves and VA at three real distances. All MCL designs showed a partial correlation higher than 0.90 and a Root Mean Square Error below 0.07 logMAR between the TF-VA of simulations and Real MCLs across subjects. The validity of the simulation approach using SimVis Gekko and in-vitro measurements was confirmed in this study, opening the possibility to accelerate the adaptation of MCLs.


Assuntos
Lentes de Contato Hidrofílicas , Lagartos , Presbiopia , Humanos , Animais , Simulação por Computador , Presbiopia/terapia , Acuidade Visual
4.
Artigo em Inglês | MEDLINE | ID: mdl-38530027

RESUMO

PURPOSE: To evaluate the clinical outcomes of the toric version of a presbyopia-correcting intraocular lens (IOL) based on the combination of a diffractive-based extended depth of focus (EDOF) pattern and a diffractive multifocal platform. SETTING: Miranza COI Bilbao, Spain. DESIGN: Prospective case series. METHODS: Thirty-five patients (51-84 years) with corneal astigmatism ranging from 0.75 to 2.19 D undergoing bilateral cataract surgery with implantation of the Synergy™ Toric II IOL (Johnson & Johnson Vision, Jacksonville, Florida, USA) were evaluated during a 3-month follow-up. Visual acuity, refraction, defocus curve, and patient-reported outcomes with the Catquest-9SF questionnaire were analyzed. A vectorial analysis was used to analyze the accuracy of astigmatic correction. RESULTS: Mean 3-month monocular postoperative uncorrected distance, intermediate (80 cm) and near (40 cm) visual acuities were 0.06±0.11, 0.13±0.12, and 0.13±0.09 logMAR, respectively. Mean monocular distance-corrected intermediate (80 cm) and near visual acuity (40 cm) were 0.11±0.12 and 0.10±0.10 logMAR, respectively. Mean binocular defocus curve showed visual acuities of 0.10 logMAR or better for defocus levels from +0.50 to -2.50 D. Residual cylinder was within ±0.50 D in 97.0% of eyes. The surgically induced astigmatism prediction error ranged between -0.49 and 0.50 D, with a mean value of 0.04±0.16 D. Mean absolute IOL rotation was 3.79±2.94º. Significant improvements were found in all Rasch calibrated scores obtained with Catquest-9SF (p<0.001). CONCLUSIONS: The implantation of the toric presbyopia correcting IOL evaluated provides an efficacious astigmatic correction while providing a fully restoration of the visual function across different distances.

5.
Semin Ophthalmol ; : 1-6, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38426308

RESUMO

PURPOSE: To assess the feasibility of the clinical use of a novel Virtual Reality (VR) training software designed to be used for active vision therapy in amblyopic patients by determining its preliminary safety and acceptance on the visual function of healthy adults. METHODS: Pilot study enrolling 10 individuals (3 men, 7 women, mean age: 31.8 ± 6.5 years) with a best-corrected visual acuity (BCVA) of ≥ .90 (decimal) in both eyes were evaluated before and after 20 minutes of exposure to the NEIVATECH VR system using the HTC Vive Pro Eye head mounted display. Visual function assessment included near (40 cm) and distance (6 m) cover test (CT), stereopsis, binocular accommodative facility (BAF), near point of convergence (NPC), near point of accommodation (NPA), accommodative-convergence over accommodation (AC/A) ratio and positive and negative fusional vergences. Safety was assessed using the VR Sickness Questionnaire (VRSQ) and acceptance using the Technology Acceptance Model ;(TAM). Changes in all these variables after VR exposure were analyzed. RESULTS: Short-term exposure to the NEIVATECH VR system only induced statistically significant changes in distance phoria (p = .016), but these changes were not clinically relevant. No significant changes were observed in VRSQ oculo-motricity and disorientation scores after exposure (p = .197 and .317, respectively). TAM scores showed a good acceptance of the system in terms of perceived enjoyment and perceived ease of use, although some concerns were raised in relation to the intention-to-use domain. CONCLUSION: Exposure to the NEIVATECH VR system does not seem to adversely affect the visual function in healthy adults and its safety and acceptance profile seems to be adequate for supporting its potential use in other populations, such as amblyopic patients.

6.
Diagnostics (Basel) ; 14(5)2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38473032

RESUMO

The VEMoS-AXL system is a new optical biometer based on spectral domain optical coherence tomography (SD-OCT) that has been tested in terms of intrasession repeatability and compared with a swept-source optical coherence tomography biometer (SS-OCT), which is recognized as the gold standard for the performance of an agreement analysis. A biometric analysis was performed three consecutive times in 120 healthy eyes of 120 patients aged between 18 and 40 years with the SD-OCT system, and afterwards, a single measurement was obtained with the SS-OCT system. Within-subject standard deviations were 0.004 mm, 4.394 µm, and 0.017 mm for axial length (AL), central corneal thickness (CCT), and anterior chamber depth (ACD) measures obtained with the SD-OCT biometer, respectively. The agreement between devices was good for AL (limits of agreement, LoA: -0.04 to 0.03 mm) and CCT (LoA: -4.36 to 14.38 µm), whereas differences between devices were clinically relevant for ACD (LoA: 0.03 to 0.21 mm). In conclusion, the VEMoS-AXL system provides consistent measures of anatomical parameters, being most of them interchangeable with those provided by the SS-OCT-based gold standard.

7.
J Refract Surg ; 40(2): e98-e107, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38346118

RESUMO

PURPOSE: To determine the prevalence of opacification of a hydrophylic intraocular lens (IOL) with hydrophobic coverage and the percentage of explantations required, determining possible risk factors associated with these opacifications. METHODS: This ambispective study enrolled 575 eyes of 296 patients (age 36 to 87 years) that underwent cataract surgery between 2010 and 2017 with implantation of different models of Lentis Mplus IOLs: LS-312-MF30, LS-313-MF15, LS-313-MF30, LU-313-MF30, and LU-313-MF30T (Oculentis GmbH). Visual, refractive, and slit-lamp biomicroscopic changes were evaluated in a long-term follow-up. The percentage of cases with IOL opacification and the percentage of cases in which IOL explantation was required due to such opacifications were calculated at each visit. Five of the explanted IOLs from this series could be analyzed by scanning electron microscopy (SEM-EDX). RESULTS: IOL opacification developed in 63 eyes (11.0%). With 95% confidence, the prevalence of IOL opacification was between 842 and 1,401 cases per 10,000 eyes. The time elapsed between surgery and the presence of IOL opacification ranged between 0 and 9.3 years (mean: 4.7 ± 2.2 years). No significant differences in terms of IOL opacification rate were found according to gender (P = .378). No significant differences were found in arterial hypertension, diabetes, hypothyroidism, or hyperthyroidism rates between eyes with or without IOL opacification (P ≥ .053). IOL explantation was needed in 9 eyes (1.57%). SEM-EDX analysis confirmed the presence of rough areas on the IOL surface containing different components, such as calcium, phosphorous, copper, or nitrogen. CONCLUSIONS: The prevalence of opacification with time in Lentis Mplus IOLs is high, with no systemic risk factors associated with this complication, suggesting that it may be attributable to the material and/or the manufacturing process. [J Refract Surg. 2024;40(2):e98-e107.].


Assuntos
Lentes Intraoculares , Lentes Intraoculares Multifocais , Facoemulsificação , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Implante de Lente Intraocular/efeitos adversos , Prevalência , Refração Ocular , Lentes Intraoculares/efeitos adversos , Complicações Pós-Operatórias/epidemiologia
8.
Biomimetics (Basel) ; 9(2)2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38392119

RESUMO

Implementing in silico corneal biomechanical models for surgery applications can be boosted by developing patient-specific finite element models adapted to clinical requirements and optimized to reduce computational times. This research proposes a novel corneal multizone-based finite element model with octants and circumferential zones of clinical interest for material definition. The proposed model was applied to four patient-specific physiological geometries of keratoconus-affected corneas. Free-stress geometries were calculated by two iterative methods, the displacements and prestress methods, and the influence of two boundary conditions: embedded and pivoting. The results showed that the displacements, stress and strain fields differed for the stress-free geometry but were similar and strongly depended on the boundary conditions for the estimated physiological geometry when considering both iterative methods. The comparison between the embedded and pivoting boundary conditions showed bigger differences in the posterior limbus zone, which remained closer in the central zone. The computational calculation times for the stress-free geometries were evaluated. The results revealed that the computational time was prolonged with disease severity, and the displacements method was faster in all the analyzed cases. Computational times can be reduced with multicore parallel calculation, which offers the possibility of applying patient-specific finite element models in clinical applications.

9.
Graefes Arch Clin Exp Ophthalmol ; 262(5): 1443-1453, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38197992

RESUMO

PURPOSE: The main purpose of this study was to perform an immunohistochemical, functional, and anatomical evaluation of patients with idiopathic epiretinal membrane (ERM). METHODS: Twenty-four specimens of idiopathic ERM from 24 consecutive patients who underwent 23 G pars plana vitrectomy for ERM and internal limiting membrane (ILM) peeling at the San Juan University Hospital in Alicante (Spain) in 2019 were analyzed. All patients underwent a complete ophthalmological examination including measurement of best corrected visual acuity (BCVA) and macular analysis by spectral-domain optical coherence tomography (SD-OCT) at the time of diagnosis and 3 months after surgery. Specific glial fibrillar acid protein antibodies (GFAP) and S100 calcium-binding protein ß (S100ß) immunostaining markers were used to identify the macroglial component of the ERM, Müller cells, and astrocytes. Ionized calcium-binding adapter molecule 1 protein (Iba1) antibodies were used as specific markers for inflammatory cells, such as microglia and macrophages. RESULTS: Mean preoperative BCVA measured with Snellen chart was 0.3 and 0.6 preoperatively and at 3 months after surgery, respectively. SD-OCT identified 15 patients (62.5%) with a disruption of the outer retinal hyperreflective bands. The immunohistochemical study showed the presence of Müller cells in almost all cases (91.6%), as well of abundant microglia and macrophages. Microglia and macrophages were more frequently present in earlier stages of ERM. Microglia were present in ERM independently of the outer retinal hyperreflective bands integrity as measured by SD-OCT. A greater presence of macrophages was found in those ERMs with no outer retinal hyperreflective band disruption. CONCLUSIONS: Müller cells seem to be the most frequent cell group in ERMs, with also presence of microglia cells and macrophages. Astrocytes were more frequently found in early stages of ERMs. Microglia and macrophages were most frequent in ERMs with early stage (1, 2, or 3) than in advanced stages (4).


Assuntos
Membrana Epirretiniana , Humanos , Membrana Epirretiniana/diagnóstico , Membrana Epirretiniana/cirurgia , Retina , Vitrectomia/métodos , Membrana Basal/cirurgia , Tomografia de Coerência Óptica/métodos , Estudos Retrospectivos
10.
Comput Biol Med ; 170: 107870, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38217971

RESUMO

A biomechanical model that simulates the physiological pressure load on the cornea without considering the stresses in vivo will result in an overstress or underestimation of the stress field and incorrect deformation of the corneal structure. Therefore, it is essential to propose numerical models that consider the stress-free geometry of the cornea. In this study, the Displacement and Pre-stress methods were compared to obtain the stress-free geometry (S-FG) and the physiological estimated geometry (P-EG), based on the patient-specific geometric behavior and the computational time required to reach each geometry. The same shape and contour conditions were considered in the models obtained from both methods for each of the pathological scenarios analyzed. Both methods behaved differently to obtain the free geometry, and this difference increased with the severity grade of the disease. However, they behaved in a similar way to reach the physiological estimated geometry. The Displacement method required a lower computational cost to reach the free geometry, with both methods presenting a similar computational cost to obtain the physiological geometry. The stress-free geometries obtained by both methods allowed to characterize the existing biomechanical decompensation during the progression of the diseases. In conclusion, the calculation of the stress-free corneal geometry associated to the clinically measured intraocular pressure with the Displacement and Prestress Methods in keratoconus eyes allows the development of accurate and useable models in clinical practice in real time. This displacement method shows some benefits in terms of computational cost.


Assuntos
Ceratocone , Humanos , Fenômenos Biomecânicos , Córnea , Tonometria Ocular , Pressão Intraocular
11.
Artigo em Inglês | MEDLINE | ID: mdl-38240175

RESUMO

PURPOSE: To assess the impact of 3 months of orthokeratology (ortho-k) contact lenses (CLs) for myopia correction on the corneoscleral profile, as changes in scleral geometry could serve as indirect evidence of alteration in the corneal biomechanical properties. METHODS: Twenty subjects (40 eyes) were recruited to wear ortho-k lenses overnight; however, after discontinuation (two CL fractures, one under-correction and two non-serious adverse events), 16 subjects (31 eyes) finished a 3-month follow-up. Corneoscleral topographies were acquired using the Eye Surface Profiler (ESP) system before and after 3 months of lens wear. Steep (SimKs) and flat (SimKf) simulated keratometry and scleral sagittal height measurements for 13-, 14- and 15-mm chord lengths were automatically calculated by the ESP software. Additionally, sagittal height and slope were calculated in polar format from 21 radii (0-10 mm from the corneal apex) at 12 angles (0-330°). Linear mixed models were fitted to determine the differences between visits. RESULTS: SimKs and SimKf were increased significantly (p ≤ 0.02). The sagittal height in polar format increased significantly (p = 0.046) at a radius of 2.5 mm for 150°, 180°, 210° and 240° orientations and at a radius of 3.0 mm for 210°. Additionally, the slope in polar format significantly decreased (p ≤ 0.04) at radii ranges of 0.0-0.5, 0.5-1.0 and 1.0-1.5 mm for multiple angles and at a radii range of 5.0-5.5 mm for 90°. It also increased significantly (p ≤ 0.045) at a radii range of 1.5-2.0 mm for 30° and at radii ranges of 2.0-2.5, 2.5-3.0 and 3.0-3.5 mm for multiple angles. No significant changes were found for any parameter measured from the scleral area. CONCLUSIONS: Three months of overnight ortho-k lens wear changed the central and mid-peripheral corneal geometry as expected, maintaining the peripheral cornea and the surrounding sclera stability.

12.
Ophthalmol Ther ; 13(3): 775-790, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38240999

RESUMO

INTRODUCTION: To evaluate and compare the clinical outcomes of two toric presbyopia-correcting intraocular lenses (IOLs). METHODS: Non-randomized prospective comparative study including 86 eyes of 51 patients (age 43-83 years) that underwent cataract surgery with implantation of one of the following two IOLs: TECNIS Toric Synergy (Johnson & Johnson Vision) (Synergy group) or AT LISA tri toric 939MP (Carl Zeiss Meditec) (ATLISA group). Visual and refractive outcomes were evaluated during a 6-month follow-up. RESULTS: At 6 months after surgery, all eyes achieved uncorrected distance visual acuity 20/25 or better in both groups, whereas 96.2% and 100% of eyes achieved uncorrected near visual acuity (UNVA) 20/25 or better in the ATLISA and Synergy groups, respectively. All eyes achieved postoperative mesopic UNVA 20/30 or better in both IOL groups; 96.2% and 100% of eyes had a manifest cylinder ≤ 0.50 D at 6 months in ATLISA and Synergy groups, respectively. Mean magnitude of error was 0.04 ± 0.20 and - 0.04 ± 0.09 D in ATLISA and Synergy groups, respectively (p = 0.05). In the defocus curve, significant differences were found between IOL groups for most of distance-corrected visual acuities, except those corresponding to defocus of 0 D (p = 0.268) and - 1 D (p = 0.361). CONCLUSIONS: The two toric presbyopia-correcting IOLs evaluated provide an efficacious astigmatic correction combined with a successful distance, intermediate and near visual rehabilitation. The visual performance seems to be better for most visual demands with the TECNIS Toric Synergy IOL, especially for distances closer than 40 cm.

13.
J Clin Med ; 13(2)2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38276091

RESUMO

The aim was to evaluate the safety, efficacy, and visual performance of an orthokeratology lens with an increased compression factor (ICF) of 1.25 D in a 3-month follow-up. Thirty-six myopic patients (5 males and 31 females; 24.2 ± 5.8 years) were fitted with Alexa AR (Tiedra Farmacéutica S.L., Madrid, Spain) contact lenses (CLs) and twenty participants finished the follow-up. Visual acuity (VA), subjective refraction, primary spherical and primary coma aberrations, keratometry, central pachymetry, and ocular surface evaluation were performed at baseline and after 1 night, 1 week, 1 month, and 3 months of CL wear. The differences among visits were analyzed using a repeated-measures analysis of variance or the Friedman test. The spherical equivalent decreased (p ≤ 0.005), and the uncorrected VA improved (p < 0.001) until the first week. Corneal and ocular aberrations showed a significant increase (p ≤ 0.02). A significant decrease (p < 0.001) was found for keratometry values. No significant changes were observed in either central pachymetry or ocular surface parameters among study visits. In conclusion, an orthokeratology CL with an ICF of 1.25 D provides good safety, efficacy, and visual performance in a 3-month follow-up. Seven days of orthokeratology wear are enough to achieve the full myopic compensation, resulting in satisfactory VA.

14.
Eur J Ophthalmol ; 34(1): 146-153, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37093755

RESUMO

PURPOSE: To evaluate the short-term clinical outcomes of a specific toric diffractive trifocal intraocular lens (IOL) implanted following an optimized clinical protocol in a large population. METHODS: Retrospective analysis of 337 eyes of 231 patients (mean age, 62.2 years) undergoing cataract surgery with implantation of the trifocal diffractive IOL AT.LISA tri toric 939M/MP (Carl Zeiss Meditec). A strict and careful clinical protocol was followed, including an accurate measurement of corneal astigmatism, use of a latest generation IOL power calculator, photography-based method intraoperative control of IOL alignment and IOL reposition at 1 week postoperatively if needed. Clinical outcomes in terms of visual acuity, refraction, efficacy of astigmatic correction analysed by vector analysis and patient satisfaction were evaluated during a 3-month follow-up. RESULTS: A total of 82% and 98% of eyes achieved a postoperative uncorrected distance visual acuity of 0.00 and 0.10 logMAR or better, respectively. Furthermore, 99.7%, and 100.0% of eyes showed a postoperative spherical equivalent within ± 0.50 D and ± 1.00 D, with 97.9% of eyes having a postoperative cylinder ≤ 0.50 D. Uncorrected near and intermediate visual acuities were 0.2 logMAR or better in 89.0% and 99.1% of eyes, respectively. Mean difference vector, magnitude of error and angle of error were 0.02 ± 0.14 D, 0.02 ± 0.13 D and 0.11 ± 1.18°. Patient satisfaction was referred as high or very high by 97.6% of patients. CONCLUSIONS: The implantation of the trifocal toric IOL evaluated following a careful clinical protocol provides an efficacious visual rehabilitation and astigmatic correction, leading to high levels of patient satisfaction.


Assuntos
Astigmatismo , Lentes Intraoculares , Facoemulsificação , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Desenho de Prótese , Refração Ocular , Astigmatismo/cirurgia
15.
Semin Ophthalmol ; 39(3): 185-192, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37853677

RESUMO

PURPOSE: To summarize and analyze critically the scientific evidence focused on the effectiveness of the use of hydrophilic contact lenses (HCLs) in myopia control, as well as their impact on visual quality and the involvement on the accommodative and binocular function. METHODS: This systematic review was developed selecting all original studies which evaluated HCLs for myopia control with follow-up of at least 1 year. Eligible randomized controlled trials (RCTs) were retrieved from PubMed MEDLINE and Scopus. Methodological quality of the studies was assessed using the Critical Appraisal Skills Programme (CASP) for RCTs. RESULTS: The search provided a total of 276 articles, selecting 13 according to the inclusion and exclusion criteria. The majority of studies evaluating the effectiveness of HCL showed a good efficacy in myopia progression, providing a good quality of vision. The quality of these studies was found to be suitable according to the CASP tool. The accommodative and binocular function with these lenses was evaluated in few studies, reporting a trend to an increase in the accommodative response and exophoria in near vision, while maintaining good level of stereopsis. Aberrometry and pupillometry were only studied in one trial, in which the authors did not find changes in these variables after the use of a myopia control HCL. CONCLUSIONS: There is a strong evidence about the effectiveness of different HCLs designs for slowing down myopia progression in children, providing all of them good levels of visual quality. However, there is still poor evidence about changes in accommodation and binocular function, as well as in pupil size and aberrometry with myopia control HCLs, being necessary more studies focused on this issue.


Assuntos
Lentes de Contato Hidrofílicas , Exotropia , Miopia , Criança , Humanos , Miopia/terapia , Percepção de Profundidade , Acomodação Ocular , Refração Ocular
16.
Semin Ophthalmol ; 39(1): 89-95, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37530551

RESUMO

PURPOSE: To evaluate and compare the results of dichoptic training in Argentinian children and adults with anisometropic amblyopia. METHODS: Prospective non-comparative study enrolling 41 subjects with anisometropic amblyopia (age, 6-60 years old). Two groups were differentiated according to age, children (6-16 years, 24 subjects) and adults (>17 years, 17 subjects). All patients were treated with the Bynocs® platform (Kanohi Eye Pvt. Ltd, India) following a protocol of 30 sessions of training of 30 min daily 5 times a week for 6 weeks. Changes in corrected distance visual acuity (CDVA) and binocular function (BF) score with treatment were analyzed. RESULTS: In the whole sample, CDVA in the amblyopic eye improved significantly, with a mean change of 0.30 logMAR (p < .001). Likewise, a significant improvement was also found in BF score (p < .001), with a mean change of 1.14 log units. The change achieved in CDVA was significantly correlated with the baseline CDVA in the amblyopic eye (r=-0.568, p < .001). Furthermore, no significant differences were found between age groups in the change achieved in CDVA (p = .431) and BF with therapy (p = .760). CONCLUSIONS: Dichoptic training with the digital platform evaluated provides an effective improvement of visual acuity and binocular function in children and adults with anisometropic amblyopia.


Assuntos
Ambliopia , Criança , Adulto , Humanos , Adolescente , Adulto Jovem , Pessoa de Meia-Idade , Ambliopia/terapia , Estudos Prospectivos , Visão Binocular , Acuidade Visual , Fatores de Tempo
17.
Cornea ; 43(3): 343-348, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37487176

RESUMO

PURPOSE: The aim of this study was to assess the repeatability of keratometry parameters obtained using the Eye Surface Profiler (ESP) system and their agreement with the IOL Master 500 device. METHODS: Seventy-one eyes of 71 healthy participants were evaluated. Three repeated measurements were performed using the ESP system. Simulated keratometry in the flat (SimKf) and steep (SimKs) meridians, astigmatism, and axis were obtained. The same parameters were measured using the IOL Master 500 device. The J0 and J45 vector components of the astigmatism were calculated. The intrasession repeatability was analyzed using within-subject SD (Sw) and intraclass correlation coefficient (ICC). Agreement was assessed using paired statistical tests and the Bland-Altman method. RESULTS: The Sw was 0.07 mm, 0.04 mm, 0.51 D, 0.33 D, and 0.22 D, and the ICC was 0.96, 0.98, 0.74, 0.61, and 0.55 for SimKf, SimKs, astigmatism, J0, and J45, respectively. The mean difference and limits of agreement when comparing the ESP system with the IOL Master 500 device were 0.37 mm (0.08/0.66) for SimKf ( P < 0.001), 0.18 mm (0.00/0.35) for SimKs ( P < 0.001), -0.93 D (-2.42/0.56) for astigmatism ( P < 0.001), 0.51 D (-0.22/1.24) for J0 ( P < 0.001), and 0.06 D (-0.48/0.60) for J45 ( P = 0.09). CONCLUSIONS: The ESP system provides consistent values for simulated keratometry, showing moderate consistency for astigmatism parameters. Contact lens practitioners should be aware that the ESP system and IOL Master 500 device provide different simulated keratometry from a clinically viewpoint.


Assuntos
Astigmatismo , Lentes de Contato , Humanos , Astigmatismo/diagnóstico , Reprodutibilidade dos Testes , Olho , Interferometria
18.
Biomedicines ; 11(12)2023 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-38137553

RESUMO

Multiple sclerosis (MS) is a neurodegenerative disease that affects the central nervous system which produces abnormalities in visual function, as disturbed pupillary responses, even after an episode of optic neuritis (ON). The aim was to assess different parameters of the pupillary response in MS subjects with and without ON. Therefore, 24 eyes of healthy age-matched subjects were included, 22 eyes of subjects with MS (MS group), and 13 subjects with MS with previous ON (MSON group). Pupillary parameters (ratio pupil max/min; latency; velocity and duration; contraction and dilation; and amplitude of contraction) were recorded with the MYAH topographer. Statistical analysis was performed by IBM SPSS Statistics, and parametrical or non-parametrical tests were used according to the normality of the data. MS patients did not significantly differ from healthy patients in any of the parameters analyzed (p > 0.05). Only patients with previous ON were different from healthy patients in the amplitude (40.71 ± 6.73% vs. 45.22 ± 3.29%, respectively) and latency of contraction (0.35 ± 0.13 s vs. 0.26 ± 0.05 s, respectively). The time to recover 75% of the initial diameter was abnormal in 9% of the MS subjects and 12% of MSON subjects. Based on the results of this study, the contraction process, especially latency and amplitude, was found to be affected in subjects with MS and previous ON. The degree of disability and the relation of the decrease in pupil response with other indicators of MS disease should be further investigated considering other comorbidities such as ON in the affection.

19.
Cont Lens Anterior Eye ; 46(6): 102068, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37919220

RESUMO

PURPOSE: All neophyte contact lens wearers require training on how to handle contact lenses. Currently, almost no published information exists describing the most common approaches used by those involved in such training in soft contact lens wearers. This study aimed to gather information on the approaches taken by those conducting this training worldwide. METHODS: An online survey was created in English and translated to Spanish and distributed internationally via social media, conference attendees, and professional contacts. The anonymous survey included information on workplace setting of respondents, information about the typical approaches used for application and removal of soft contact lenses, length of the appointment, and success rate with their approach. Survey responses were received between May 2021 and April 2022. RESULTS: A total of 511 individuals completed the survey and responses were received from 31 countries with 48.7% from the UK. The most common approach taught for application was to have the patient hold the upper eyelashes (84.7%) and to hold the lower eyelid with the same hand as the lens (89.4%). Lenses were applied directly to the cornea by 57.7% of the respondents. The most common approach taught for lens removal was to drag the lens inferiorly from the cornea prior to removal (49.3%). Most respondents did not use videos to aid the teaching appointment (62.0%); however, they felt that their approach was successful in most cases (90). Application and removal training sessions lasted a median of 30 min and contact lenses were typically dispensed after the instructor witnessing successful application and removal three times. CONCLUSION: Various methods are adopted globally for training of application and removal of soft contact lenses, with many advising a patient-specific approach is required for success. The results of this survey provide novel insights into soft contact lens handling training in clinical practice.


Assuntos
Lentes de Contato Hidrofílicas , Humanos , Córnea , Pálpebras , Inquéritos e Questionários
20.
Clin Exp Optom ; : 1-7, 2023 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-37944504

RESUMO

CLINICAL RELEVANCE: New digital systems are being developed for evaluating different aspects of the visual function, such as binocularity, and it is important to know their real performance in clinical practice in order to use them appropriately. BACKGROUND: The aim was to compare binocular vision measures obtained with an online digital platform with conventional measures using prisms and printed tests. METHODS: Prospective study enrolling 49 healthy patients (mean age: 35.5 ± 13.6 years). A complete visual examination was performed including measurement of near phoria (cover test), negative fusional vergence (NFV) and positive fusional vergence (PFV) ranges (prism bar), and stereopsis (24 patients Randot Stereo Test and 25 patients TNO Random Dot Test 19th edition). These same parameters were also measured with the Bynocs system (Kanohi Eye Pvt Ltd). Bland - Altman plots were used to analyse the agreement between methods. RESULTS: Digital measurement of near phoria was significantly lower than that obtained with the cover test, with a median difference (MD) of 4.71 (-0.07-20.07) prism dioptres (pd) (p < 0.001). No significant differences were found between Bynocs and prism bar methods in NFV break (MD 2.00, range -21-26 pd, p = 0.584) and recovery points (MD 0.00, range -16-24 pd, p = .571). Near PFV were significantly lower with Bynocs (break: MD -9.00, range -38-12 pd; recovery: MD -14.00, range -43-20 pd; p < 0.001). Bynocs stereoacuity threshold was significantly lower than that obtained with TNO (p = 0.004), but significantly higher compared to Randot (p < 0.001). Large and clinically relevant confidence intervals for the comparison between digital and conventional measures were detected in Passing-Bablok analysis. CONCLUSIONS: Digital measures of near phoria, NFV, PFV, and stereopsis with the Bynocs platform cannot be used interchangeably with conventional measures. The normal ranges of normality for this new tool are defined.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...